Categories
- 0086-512-58697986
- info@bestrantech.com
- bestrantech
- 0086-13862268429
High Frequency X-ray Radiograph System
High Frequency X-ray Radiograph System
I. Application:
This machine is applied to take radiography on every part of human body, such as head, limbs, chest, limbus and abdomen and etc.
II. Specification:
Item |
content |
|||
Output power |
65kW |
|||
Main inverter frequency |
60kHz |
|||
X-ray tube (Toshiba E7252X) |
Rotary anode, dual-focus |
|||
Large/ Small focus |
1.2mm/ 0.6mm |
|||
Power of large/ small focus |
75kW/ 27kW. |
|||
Anode thermal capacity |
210kJ |
|||
Tube thermal capacity |
900kJ |
|||
Rotary anode speed |
9700rpm |
|||
Anode target surface angle |
12° |
|||
mA range |
10mA-650mA |
|||
Tube voltage |
40kV-150kV |
|||
Exposure Time |
0.001s-12.5s |
|||
mAs |
0.1-630mAs |
|||
Table radiography grids |
Grid density: 103L/inch Grid ratio: 10:1; Focusing Distance: 120cm Stationary type: 18"×18" |
|||
Cassette |
Film size: 356*432mm(14”*17*) Longitudinal movement: 560mm |
|||
Mechanical Movement |
SID: |
450-1200mm |
||
X-ray tube Longitudinal movement |
1370mm |
|||
X-ray tube Rotation range around transverse axis |
±90° |
|||
X-ray tube Rotation range around X-ray tube axis |
35° |
|||
X-ray tube Rotation range around pillar |
4* 90° |
|||
Table |
Table size |
2000×760mm |
||
Table height |
≤700mm |
|||
Table transverse movement |
≥220mm |
|||
Table longitudinal movement |
≥900mm |
|||
Power supply |
380/400VAC three phase 50Hz |
|||
Operation method |
1. Close-table graphic program controlled LCD touchable screen operation 2. Wireless remote control exposure |
III. Standard Configurationt
No. |
Item |
Quantity |
1 |
High frequency and high voltage X-ray generator |
1 |
2 |
X-ray tube (Toshiba) |
1 |
3 |
Collimator |
1 |
4 |
High frequency inverted power supply electronic cabinet |
1 |
5 |
Colored LCD touch screen control box |
1 |
6 |
New integral radiography table (with pillar) |
1 |
7 |
AEC |
1 |
7. Upright Bucky Stand
1. Packing Detail: 1950*750*600mm
N.W.: 200kg G.W.: 235kg
2. The height: 1768 mm
3. Movement range of cassette: 560-1625mm
4. Max film size: 17’’ ×17’’
Film size: 5"×7"-17"×17"
5. Parameters,
Grid Density: 103L/INCH
Grid Ratio: 10:1
Focus Distance: 150cm
Features: with Stationary Filter line, 18” X18”
IV. Feature:
1. It is installed with close-table graphical colorful LCD touch screen and wireless remote control exposure, which makes the operator easy to use.
2. We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
3. human graphical LCD touch screen, intelligent and fast operation
4. It can choose KV, mAs two buttons system photograph mode and Kv, mA, S three buttons system, two photography mode could meet different users professional requirements perfectly
5. Adopt the technology of kV and mAs numeral closed loop control, real-time control of the microprocessor, which ensures the accuracy and repeatability of the output dose.
6. Be equipped with radiography parameter of multi-part, multi-posture, multi-body, adult -child physical characteristic, the operator can modify and save the parameter by himself, which makes the operation more conveniently.
7. Possess multiple automatic protection and fault clue function, which makes the operation safer and more reliable.
8. The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.
9. X-ray generator component can move round the axis of X-ray generator, cross arm and Pillar stand , be convenient with side and slanting direction projection and radiography of patient on the stretcher.
10. Be equipped with the chest stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.
11. Control console of graphic program controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.
V. Options:
1. Control console