Categories
- 0086-512-58697986
- info@bestrantech.com
- bestrantech
- 0086-13862268429
Medical Ventilator
Ventilator
Model: BT-S900B1
Introduction:
The BT-S900B1 ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. , it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Physical specifications |
|
Display |
10.4'' LCD Display |
Mode: |
pneumatically powered and electrically controlled system |
Trolley: |
Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications: |
|
Gas requirement: |
Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve |
<12.5 kPa |
Respiratory Rate |
1 ~ 99 bpm |
gas concentration output |
21% ~ 100% adjustable |
Maximum Minute ventilation |
≥18L / min |
modes of ventilation |
A/C, SIPPV、IPPV、SIMV、PSIMV、CPAP、PCV、PEEP、SIGN、SPONT, MANUAL |
Ventilator compliance |
≤30 Ml/kPa |
PEEP: |
0 ~ 1.0 kPa |
Ptr: |
-1.0kPa~1.0kPa |
IMV frequency: |
1~20 bpm |
I/E Ratio: |
4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume range |
0~2000ml |
Inspiratory Plateau: |
0~1s |
Maximum Safety Pressure |
≤ 6.0kPa |
Sigh: |
one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range: |
1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating |
Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa |
±0.2 kPa |
|
Ventilation Volume alarm: |
≥ 18L/ MIN |
Power Supply Alarm |
Ac/dc power supply are after failing to send out alarm immediately |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. |
|
Operating conditions |
|
Ambient temperature: |
10 ~ 40oC |
Relative humidity: |
no higher than 80 % |
Atmospheric pressure: |
860 hPa ~ 1060 hPa |
Power requirement: |
100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the anesthesia machine must be well grounded. |
|
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. |
|
Storage |
|
Ambient temperature: |
-15oC ~ +50oC |
Relative humidity: |
no higher than 95 % |
Atmospheric pressure: |
86 kPa ~ 106 kPa. |
|
It should be stored in a room without corrosive gas and well ventilated |
Package |
|
packaging box |
comply with the requirement of GB/T 15464 |
|
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation |
|
Moisture protection and rain protection to ensure that product is protected from natural damage. |
Safty & Alarm |
|
Gas source pressure |
Immediate alarm; “high level alarm” indicator flickers raising an audible alarm. |
Airway Pressure Alarm |
The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. |
Tidal Volume Alarm |
Lower than 50ml, The alarm will be raised after one breathing cycle. |
Ventilation Volume Alarm |
Lower: 0~12L/Min; Up: 18L/ Min |
Battery Voltage Alarm |
It alrms when the battery voltage is lower than 10.5V. |
Power On Self Test |
Self test before working, assure it's working normally. |